Heating Area

Model:ST-7800

Power :800W(±10%)

Temperature range:50°C~350°C/122℉~662℉

Heating material: Aluminum Plate

Display method: TFT display

External type thermocouple: Yes

LoT function: Yes

Linkage function: Yes

Dimensions:355(L)*293(W)*73(H)mm

Weight:≈5.1kg

 

Operating Instructions

  1. Connect the power cord to the corresponding interface on the main unit.
  2. Turn on the power switch, and the preheating platform will start heating up(the default factory setting is to heat up to 100°C/212°F).
  3. While on the main screen and with the machine’s temperature not locked, adjust the temperature value using the “”and “” buttons on the machine panel.(Temperature range: 50~500’C/122~932’FforST-7500,and 50~350°C/122~662°F for ST-7800)
  4. The machine will gradually heat up or cool down to the set temperature. When not using the machine for an extended period, please turn off the power and unplug the power cord.

 

Instructions for K-Type Thermocouple

  1. As shown in the diagram, insert the K-type thermocouple into the corresponding interface of the preheating platform host. (Note: To avoid damaging the components and the host ensure that the positive and negative terminals of the K-type thermocouple correspond to the positive and negative terminals on the machine’s panel).
  2. On the main interface of the preheating platform host, the “External Test Temperature will display the actual temperature data measured by the thermocouple, making it convenient for users to test the actual temperature of the heating product.

 

 LoT Function 

 

 

RS485 Communication (Slave Mode):

  1. Set the preheating platform master/slave linkage mode to M3 (Slave Mode).
  2. Use the communication cable as shown in the diagram to connect this product’s RS485interface to the computer’s USB interface.
  3. On the computer side, use upper computer software to control the preheating platform machine with commands.

 

 

Quick Parameter Groups Rest:

 

Factory Reset:

  • To restore factory settings, a password must be entered. After entering the correct password, the machine will automatically restart and restore the factory settings.
Quick Temperature Groups
  • In the Quick Parameter Group function, three sets of quick temperature can be customized.(Factory defaults for quick parameters are [1]: 80°C/176°F, [2]: 200°C/392°F, [3]: 350°C/662°F.

Quick Parameter[1]: Temperature range can be set from 50 to 500’C/122 to 932°F

Quick Parameter[2]: Temperature range can be set from 50 to 500’C/122 to 932°F, and operating time can be set from 000 to 900 seconds.

Quick Parameter[3]:  For ST-7500, Temperature 1 range is 50 to 300°C/122 to 572°F, Temperature 2 range is 300to 500’C/572 to 932°F.

For ST-7800, Temperature l range is 50 to 200°C/122 to 392°F, Temperature 2 range is 200to 350’C/392 to 662’F, and operating time can be set from 000 to 900 seconds.

 

Temperature Lock

 

Temperature Compensation